Duct Design Software
h2x duct design software sizes every duct, adds the fitting losses and gives you the fan duty, all on your floor plan. Then it exports drawings, reports and Revit models.
Trusted by mechanical engineers worldwide
5.0 on Google
4.8 on Capterra
What Is Duct Design Software?
Duct design software lays out supply, return and extract ductwork, then sizes each duct to velocity and pressure drop limits. Then it adds the fitting losses, finds the index run and gives the fan duty. In h2x, the ductwork sits in the same model as the pipework and the room loads, so the sizes update when the design changes.
In practice, engineers use h2x to:
- Size round and rectangular ductwork to velocity and pressure drop limits
- Add the losses through fittings, dampers and grilles, and find the index run
- Work out the fan duty for each air handling unit
- Export drawings, a calculation report, a ductwork schedule, AutoCAD files and Revit models
Who Uses h2x Duct Design Software?
h2x does a different job for each team, from the first duct size to the bid.
DESIGN CONSULTANTS
Design, Review and Document
Mechanical engineers use h2x to design and document ductwork. Every duct shows its size, airflow, velocity and pressure drop, so a senior engineer can review a whole system in one place. Then sized designs go straight to Revit or AutoCAD.
COMMERCIAL CONTRACTORS
Check, Size and Price
Mechanical contractors use h2x to check a consultant’s duct sizes before they install, and to size design-and-build jobs themselves. In addition, the bill of materials lists every duct, fitting, damper and grille on the job, ready to price at your own rates.
Why Use h2x as Your Duct Design Software?
Most duct design still runs through separate tools: a ductulator or sizing spreadsheet, a fan duty calculation and a CAD package. So every change means entering the same data again. Instead, h2x keeps the layout, sizing, fan duty and drawings in one model, so a change in one place carries through to the rest.
Duct Layout
First, draw supply, return and extract ductwork on the floor plan, from each air handling unit to every grille. Then move a run or a fitting, and the ductwork stays connected.
Duct Sizing
h2x sizes every duct to the maximum velocity and pressure drop you set for each system, as round or rectangular duct. Then it upsizes any duct that would break the limits.
Pressure Loss and Fan Duty
h2x adds each fitting’s loss to the duct friction and traces the index run to the hardest grille to serve. Then it gives the fan duty from every loss on that run.
Drawings and Exports
Export a PDF drawing set with your own title blocks, AutoCAD files mapped to your layers and blocks, or a Revit model. You can also add a calculation report and a bill of materials.
How Duct Design Works in h2x
Eight steps take a floor plan to sized, documented ductwork, all in one project.
- Import the planUpload the architect’s PDF or DWG and set the scale. When a new revision arrives, replace the plan and keep your design.
- Place the equipmentThen add air handling units, rooftop units, fans and supply, return and extract grilles from the design toolbar.
- Set the limitsFor each system, choose maximum velocity, maximum pressure drop or both, separately for risers, mains, branches and connections. Then pick round or rectangular duct and a sizing mode.
- Draw the ductworkThen connect each unit to its grilles. The airflow on every section adds up from the grilles it serves, while diffuser airflows can follow each room’s heat gain.
- Size every ductThen h2x sizes each section to its limits and upsizes it where a smaller duct would break them. A size you fix or cap gets a warning instead.
- Add dampers and componentsPlace balancing dampers, coils and other components on the runs, so h2x includes each one’s pressure drop.
- Find the fan dutyh2x then traces the index run. Then it gives the fan duty from every duct, fitting and component on it, plus the unit’s own internal pressure drop.
- Review and exportCheck velocity and pressure drop on heat maps and in 3D, then export drawings, reports and models.
For the method behind duct sizing, including velocity limits and friction rates, see our guide to how to calculate duct size.
Sizing an Office Supply System in h2x
For example, this supply system comes from an h2x model of an office. One rooftop unit, RTU-1, supplies 944 L/s (2,000 CFM) to eight ceiling diffusers at 118 L/s (250 CFM) each. The mains were limited to 6.1 m/s (1,200 fpm) and 1.0 Pa/m (0.12 in. w.c. per 100 ft). Similarly, the branches were limited to 4.1 m/s (800 fpm) and 0.57 Pa/m (0.07 in. w.c. per 100 ft).
| Result | Metric | Imperial |
|---|---|---|
| Main duct at the unit | 600 × 300 mm | 24 × 12 in |
| Main duct at the last diffuser | 250 × 150 mm | 10 × 6 in |
| Branch to each diffuser | 300 × 150 mm | 12 × 6 in |
| Highest main velocity | 5.5 m/s | 1,084 fpm |
| Index run | 26 m, 9 fittings | 85 ft, 9 fittings |
| Loss through the last diffuser | 25 Pa | 0.10 in. w.c. |
| External static on the index run | 94 Pa | 0.38 in. w.c. |
As a result, h2x stepped the main down from 600 × 300 mm to 250 × 150 mm as the airflow fell, and kept every section inside its limits. The 94 Pa (0.38 in. w.c.) covers every duct and fitting on the index run and the last diffuser. Then h2x adds the unit’s internal pressure drop to give the fan duty.
Real Mechanical Design Results With h2x
Consultants use h2x to size heating and water systems, so pump duties keep up when the layouts change.

How Kench Consultants Cut a Week of Design to 1.5 Days
Kench Consultants designed the mechanical services for seven large private houses in South London. Each has an air source heat pump feeding a hot water cylinder and a low-temperature underfloor heating circuit, plus boosted cold water. The team designed the heating and domestic water for all seven in h2x in 1.5 working days, whereas the same scope typically takes up to five.
Associate Director Rob Adams called the speed of h2x, with pump duties and pipe sizes updating automatically, “the biggest advantage”.

What h2x Duct Design Software Calculates
As a result, every duct carries its results, on the plan and in the calculation report.
| Calculation | What you get |
|---|---|
| Airflow | The flow on every duct section, added up from the grilles it serves, in L/s or CFM |
| Duct size | Round or rectangular, sized to the maximum velocity, maximum pressure drop or both, set for risers, mains, branches and connections |
| Sizing mode | Recommended sizes only, step increments or unrestricted, with a target width-to-height ratio |
| Velocity | On every section, in m/s or fpm |
| Duct pressure loss | Friction loss by the Darcy-Weisbach equation, plus the loss through each fitting |
| Index run | The path to the hardest grille to serve, shown on the plan |
| Fan duty | The airflow and pressure the fan must deliver, from every duct, fitting, damper and grille on the index run, plus the unit’s internal pressure drop |
| Return and extract | Sized the same way as supply ductwork |
| Design checks | h2x upsizes ducts to stay within the limits, and warns where a fixed or capped size can’t. Heat maps also show velocity and pressure drop |
| Exports | PDF drawings, calculation report, ductwork schedule, bill of materials, AutoCAD and Revit |
h2x’s ventilation calculations are verified by CIBSE, and its calculations are also aligned with ASHRAE methods.
What Mechanical Engineers Say About h2x
Mechanical engineers use h2x for ductwork and system sizing, as well as Revit exports.
The software is very easy to use. The heat load calculation function is particularly impressive.
We’ve been using h2x for our mechanical design work and are consistently impressed. Highly recommended.
h2x is great software, our company use it nearly every day. It is easy to use with direct conversion from h2x to Revit.
h2x is fantastic software. It is very easy to use and the ability to output to Revit is a fantastic time saver.
Get Up and Running Quickly
h2x gives your team the training and support they need to get up to speed quickly, with demos, live sessions and help available when they need it.
- 1:1 Demonstrations: See how h2x fits your team's projects and workflows.
- Live Training: Learn the platform with guidance from the h2x team.
- h2x Uni: Build your knowledge through dedicated learning resources.
- Video Tutorials: Follow step-by-step guidance whenever you need it.
- Technical Support: Get live, in-app help from h2xperts and MEP experts.
Duct Design Software FAQs
Which software sizes ductwork and calculates pressure loss and fan duty?
h2x does all three in one model. First, it sizes every duct to the velocity and pressure drop limits you set, calculates friction loss with the Darcy-Weisbach equation and adds each fitting’s loss. Then it finds the index run and gives the fan duty, including the unit’s internal pressure drop.
Can I design and size pipework and ductwork in one place?
Yes. In h2x, ductwork and pipework sit on the same plan and in the same model. For example, an air handling unit’s ductwork and its chilled and heating water pipework are designed together, so there’s no second model to keep in step.
How does h2x size ducts?
Each system has its own sizing method: maximum velocity, maximum pressure drop or both, set separately for risers, mains, branches and connections. Ducts can also be round or rectangular, sized from recommended sizes only, in step increments or unrestricted, with a target width-to-height ratio. You can also override the size or material of any duct.
How does h2x calculate duct pressure loss and fan duty?
First, h2x calculates the friction loss on each section with the Darcy-Weisbach equation and adds the loss through every fitting, damper and grille. Then it traces the index run, the path to the hardest grille to serve, and adds the unit’s internal pressure drop to give the fan duty.
Can h2x replace a duct sizing spreadsheet or ductulator?
For a whole system, yes. h2x sizes every duct at once, so the sizes stay up to date as the layout changes. For a single duct, however, the free duct size calculator or the online ductulator is quicker.
What can I export from h2x for ductwork?
A PDF drawing set with your own cover sheet and title blocks, AutoCAD files mapped to your layers and blocks, or a Revit model. In addition, h2x exports a calculation report, a ductwork schedule in Excel and a bill of materials listing ducts, fittings, dampers, grilles and air handling units.
Does h2x design residential and commercial ductwork?
Yes. h2x handles small residential systems as well as large commercial networks, with supply, return and extract runs all sized the same way. For the heat loads, chilled and heating water pipework and fan duties in the same model, see our HVAC design software.
Does h2x work in metric and imperial units?
Yes. Each project runs in metric or imperial units, so airflow shows in L/s or CFM, velocity in m/s or fpm and pressure drop in Pa or in. w.c. For example, the worked example above shows the same office system in both.
Design Your Next Duct System in h2x
Design up to four times faster than traditional methods. Book a demo so we can show you h2x on a project like yours.